HA501839U001

Documents

49 pages
12 views

Please download to get full document.

View again

of 49
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Share
Description
Fgg
Transcript
  Option Modules Modbus RTU Option HA501839U001 Issue 4 Technical Manual aerospace aerospace climate control climate controlelectromechanical  ltration filtration fluid & gas handling fluid & gas handling hydraulics hydraulics pneumatics pneumatics process control process control sealing & shielding sealing & shielding ENGINEERING  YOUR SUCCESS    AC30 Modbus RTU Option Technical Manual HA501839U001 Issue 4 Copyright 2016 Parker Hannifin Manufacturing Limited  All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any form or by any means to persons not employed by a Parker company without written permission from Parker Hannifin Ltd. Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Parker cannot accept responsibility for damage, injury, or expenses resulting therefrom. Parker Hannifin Manufacturing Limited is referred to throughout this document as Parker. WARRANTY The general terms and conditions of sale of goods and/or services of Parker Hannifin Europe S à rl, Luxembourg, Switzerland Branch, Etoy, apply to this product unless otherwise agreed. The terms and conditions are available on our website www.parker.com/termsandconditions/switzerland.    FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. The above disclaimer is being specifically brought to the user’s attention and is in addition to and not in substitution to the Exclusions and Limitations on Liability which are set out in the terms and conditions of sale.    Safety Information Requirements IMPORTANT: Please read this information BEFORE installing the equipment. Intended Users This manual is to be made available to all persons who are required to install, configure or service equipment described herein, or any other associated operation. The information given is intended to highlight safety issues, EMC considerations, and to enable the user to obtain maximum benefit from the equipment. Complete the following table for future reference detailing how the unit is to be installed and used. INSTALLATION DETAILS Model Number (see product label)   Where installed (for your own information)   Application Area The equipment described is intended for industrial motor speed control utilising AC induction or AC synchronous machines. Personnel Installation, operation and maintenance of the equipment should be carried out by competent personnel. A competent person is someone who is technically qualified and familiar with all safety information and established safety practices; with the installation process, operation and maintenance of this equipment; and with all the hazards involved. Product Warnings DANGER Risk of electric shock WARNING Hot surfaces Caution Refer to documentation   Earth/Ground Protective Conductor Terminal   CAUTION! APPLICATION RISK   The specifications, processes and circuitry described herein are for guidance only and may need to be adapted to the user’s specific application. We cannot guarantee the suitability of the equipment described in this Manual for individual applications. RISK ASSESSMENT Under fault conditions, power loss or unintended operating conditions, the drive may not operate as intended. In particular:   Stored energy might not discharge to safe levels as quickly as suggested, and can still be present even though the drive appears to be switched off   The motor's direction of rotation might not be controlled   The motor speed might not be controlled   The motor might be energised  A drive is a component within a drive system that may influence its operation or effects under a fault condition. Consideration must be given to:   Stored energy   Supply disconnects   Sequencing logic   Unintended operation
Advertisement
Related Documents
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks
SAVE OUR EARTH

We need your sign to support Project to invent "SMART AND CONTROLLABLE REFLECTIVE BALLOONS" to cover the Sun and Save Our Earth.

More details...

Sign Now!

We are very appreciated for your Prompt Action!

x